Chicago Pneumatic CPX Air Dryer – Compressed Air Refrigerant Dryer

Call for Price

The CPX series dryer creates dry quality air that prolongs the life of tools and equipment at the processs end. This is a compact, high efficiency device that meets continuous air demand.

Chicago Pneumatic CPX Air Dryer – Compressed Air Refrigerant Dryer

The Chicago Pneumatic CPX Air Dryer series dryer creates dry quality air that prolongs the life of tools and equipment at the processs end. This is a compact, high efficiency device that meets continuous air demand.

The CPX refrigerant dryers guarantee dry and qualitative compressed air which prolongs the lifetime
of your equipment and ensures a superior production quality. Water vapour is eliminated, avoiding
corrosion in your compressed air network and tools. All in all this lowers your maintenance costs and
improves your overall production process for complete peace of mind.
Pressure Dew Point 7-10°C
• High efficiency plate-fin heat exchanger
• Low relative humidity in outlet air
• Professional water removing function
Professional Energy Efficiency
• 50% less energy consumption compared to
shell and tube type dryers
• Optimized refrigeration system
Environment Safety
• Low (GWP) global warming potential
• Low (ODP) ozone depletion potential
• Energy saving
Reliable
• Industrial grade refrigeration compressor
• Digital controller & PDP display
• Optimised piping with 3 stage leak test

Chicago Pneumatic CPX Air Dryer

Description

Chicago Pneumatic CPX Air Dryer – Compressed Air Refrigerant Dryer

The CPX series dryer creates dry quality air that prolongs the life of tools and equipment at the processs end.

This is a compact, high efficiency device that meets continuous air demand.

The CPX refrigerant dryers guarantee dry and qualitative compressed air which prolongs the lifetime
of your equipment and ensures a superior production quality. Water vapour is eliminated, avoiding
corrosion in your compressed air network and tools. All in all this lowers your maintenance costs and
improves your overall production process for complete peace of mind.
Pressure Dew Point 7-10°C
• High efficiency plate-fin heat exchanger
• Low relative humidity in outlet air
• Professional water removing function
Professional Energy Efficiency
• 50% less energy consumption compared to
shell and tube type dryers
• Optimized refrigeration system
Environment Safety
• Low (GWP) global warming potential
• Low (ODP) ozone depletion potential
• Energy saving
Reliable
• Industrial grade refrigeration compressor
• Digital controller & PDP display
• Optimised piping with 3 stage leak test

Refrigerant circuit
The refrigerant circuit compresses and expands the refrigerant medium in a circular system in order
to efficiently transfer heat from the wet compressed air to the atmosphere. The CPX dryer refrigerant
circuit is designed as a whole and only uses components of high and reliable quality, supplied by
globally recognized manufacturers.
Air circuit
Wet compressed air flows directly through the CPX dryer’s internal 3-in-1 heat exchanger, where in
the 3 key dryer functions are combined. Firstly the wet compressed air is cooled down to condensate
the moisture, secondly this condensed moisture will be collected and drained out. Finally the dried
compressed air is re-heated before it enters the factory’s pipework.
1 Refrigerant Separator
Ensures that only refrigerant gas can enter the
compressor, as liquid would cause damage.
2 Refrigerant Compressor
Brings the gaseous refrigerant to a high
pressure and a high temperature.
3 Digital controller
To show operation status and inform alarm
information to users.
4 Max. Pressure Switch
Protects by ensuring that the refrigerant gas
never exceeds the maximal pressure.
5 Condenser Fan
Efficiently provides constant flow of ambient air to the air
condenser (only for air cooled).
6 Condenser
Cools the refrigerant slightly so that it can change
from gas to liquid; refrigerant is more effective in the
liquid state.
7 Capillary Filter
Protects the expansion device from harmful particles.
8 Capillary Tube
Reduces the refrigerant’s pressure, thereby lowering
its temperature and increasing its cooling capacity; the
refrigerant is now almost all liquid, with some residual
gas. Capillary tubes are expansion devices that are
extremely reliable, and stabilize the dew point of the dryer.
9 Hot Gas Bypass
Regulates the amount of refrigerant passing through
the air-to-refrigerant heat exchanger, ensuring a stable
pressure dew point, and eliminating the chance of the
condensate freeing.
10 Air Inlet
Hot saturated air enters the dryer.
11 Air-To-Refrigerant Heat Exchanger
Transfers heat from the compressed air to
the cold refrigerant, forcing water vapor in the
compressed air to condense.
12 Air-To-Air Heat Exchanger
Cools down the air inlet whilst re-heating
the outlet air.
13 Water Separator
Collects and drains out condensate from the cooled
air flow. 3-in-1 aluminum heat exchangers combine
above points 11,12 and 13 making them highly
efficient and reliable..
14 Automatic Drain
Removes the free water collected in the water separator.
15 Air Outlet
Re-heats the outgoing air to prevent
condensation on the factory’s pipework.

Chicago Pneumatic CPX Air Dryer

https://adaptiveair.com.au/product/cpx-series-compressed-air-refrigerant-dryer/